Electron Microprobe Laboratory

CAMECA SX100 Electron Microprobe

Alan Patchen sits with one of the Department's major analytical instruments, the Cameca SX-50 Electron Microprobe with four wavelength spectrometers and and energy dispersive system (EDS).The Cameca SX-100 electron microprobe (EMP) in the Department of Earth & Planetary Sciences, University of Tennessee at Knoxville, is equipped with 4 wavelength dispersive spectrometers (WDS), a PGT Sahara energy dispersive spectrometer (EDS), plus cathodoluminescence (CL) and high-speed backscattered electron (BSE) detectors. The Cameca is controlled by the PC-based "Peaksight" software, and is internet-connected for efficient data and image transfer. 

Analytical Capability:

  • Analysis of elements ranging in atomic number from Be to U
  • Analysis of elements ranging in concentration from 100% to 10 ppm
  • Automated full matrix corrections using the PAP, Pouchou & Pichoir (1987) model
  • Analysis of up to 40 elements per analytical point

CAMECASample preparation:

  1. Cutting with a saw and trimming to a size that can be mounted.
  2. Mounting in one of two ways:
    • Into a resin block: the sample is placed in a circular mold and impregnated with a resin. This option allows for additional imaging with an optical microscope using reflected light.
    • Onto a glass slide: the sample is affixed to a standard size 1 inch glass slide with resin for further lapping and polishing. This method allows imaging to be achieved using both transmitted and reflected light microscopy.
  3. Removal of excess sample and grinding to ensure the top and base of resin blocks are parallel.
  4. Lapping to produce a smooth surface. This may be performed by hand or on an automated jig using fine (600 grade) abrasive - usually silicon carbide.
  5. Polishing - carried out in steps on a special cloth with a slurry of very-fine diamond, ranging in size from 6 to 0.3 microns.

Carbon-coating:
Prior to analysis of most samples - particularly those containing minerals – the specimen disk will need to be coated with a thin film of conducting media to dissipate excess charge produced by the electron beam. Usually carbon is used, and the film is typically 30 nanometers thick.


CLICK IMAGE TO ENLARGE

Information for Lab users:

  • Departmental users
    • Students who wish to learn to use this Electron Microprobe for their research should enroll in the Fall course EPS-568 (Geochemical Analysis) by Prof. Larry Taylor.
    • All users must have prior EMP experience.
  • Collaborative Research with other institution is welcome.
    • The scheduling of lab time should be discussed with lab manager.
  • Commercial Users should first contact Prof. Taylor.